Ethyl Acetate Chemical Storage Specifications

Compliant storage and rental solutions for Ethyl Acetate (C4H8O2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Flammable hazardFlammable Storage

Chemical formula

Ethyl Acetate molecular formula

About Ethyl Acetate

Ethyl acetate is used as a solvent for varnishes, lacquers, dry cleaning, stains, fats and nitrocellulose. It is released during the production of artificial silk and leather, and during the preparation of photographic films and plates.

Structured hazard data

Hazard class
See SDS
Storage category
Flammable Storage
Flammable
Yes
Flash point
-4 C
Storage temperature
2-30 C
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE)

Flammable liquids (Category 2), H225 Eye irritation (Category 2A), H319 Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336

Fire Suppression System

Dry Chemical fire suppression is recommended for Ethyl Acetate

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Ethyl acetate (C4H8O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Ethyl acetate should account for its listed hazards, climate control needs (2-30 C), and segregation requirements. not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE)

Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.

Properties: a) Appearance Form: clear, liquid Color: colorless b) Odor fruity c) Odor Threshold 0.1 ppm d) pH No data available e) Melting point/freezing point Melting point/range: -84 °C (-119 °F) f) Initial boiling point and boiling range 76.5 - 77.5 °C 169.7 - 171.5 °F g) Flash point -4 °C (25 °F) - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits Upper explosion limit: 11.5 %(V) Lower explosion limit: 2.1 %(V) k) Vapor pressure No data available l) Vapor density 3.04 m) Density 0.90 g/cm3 at 20 °C (68 °F) Relative density No data available n) Water solubility No data available o) Partition coefficient: n-octanol/water log Pow: 0.73 - Bioaccumulation is not expected., (Lit.) p) Autoignition temperature No data available

Matched to this chemical

Recommended storage solutions for Ethyl Acetate

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    • 228 Square Feet storage
    View product
  • Fire-rated4 HourChemical Storage

    FireSAFE 4X

    • 4-Hour Fire-Rated
    • 8 ft x 10 ft
    • 12 Barrels
    • 55 Gal Storage Drums
    • 48 Square Feet storage
    View product
  • Fire-rated4 hourChemical Tote Storage

    Single Tote & Pallet Storage

    • 4-Hour Fire-Rated 6' Deep 1-Tote-Deep
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Ethyl acetate be stored?

Store Ethyl acetate in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: 2-30 C. Compatibility notes: not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE) US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Ethyl acetate flammable?

Yes — Ethyl acetate is flagged as a flammable hazard in this database (Yes). Flash point: -4 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.

What hazard class is Ethyl acetate?

Ethyl acetate is listed as: Consult the SDS and applicable hazard classification. Flammable liquids (Category 2), H225 Eye irritation (Category 2A), H319 Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336

What fire suppression is recommended for Ethyl acetate?

Dry Chemical fire suppression is generally recommended for Ethyl acetate (C4H8O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Ethyl acetate storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Ethyl acetate. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.