
FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Ethyl Acetate (C4H8O2). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Ethyl acetate is used as a solvent for varnishes, lacquers, dry cleaning, stains, fats and nitrocellulose. It is released during the production of artificial silk and leather, and during the preparation of photographic films and plates.
Flammable liquids (Category 2), H225 Eye irritation (Category 2A), H319 Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336
Dry Chemical fire suppression is recommended for Ethyl Acetate
Guidance: Dry Chemical fire suppression is generally recommended for Ethyl acetate (C4H8O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam. LARGE FIRE: Water spray, fog or alcohol-resistant foam
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Ethyl acetate should account for its listed hazards, climate control needs (2-30 C), and segregation requirements. not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE)
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: a) Appearance Form: clear, liquid Color: colorless b) Odor fruity c) Odor Threshold 0.1 ppm d) pH No data available e) Melting point/freezing point Melting point/range: -84 °C (-119 °F) f) Initial boiling point and boiling range 76.5 - 77.5 °C 169.7 - 171.5 °F g) Flash point -4 °C (25 °F) - closed cup h) Evaporation rate No data available i) Flammability (solid, gas) No data available j) Upper/lower flammability or explosive limits Upper explosion limit: 11.5 %(V) Lower explosion limit: 2.1 %(V) k) Vapor pressure No data available l) Vapor density 3.04 m) Density 0.90 g/cm3 at 20 °C (68 °F) Relative density No data available n) Water solubility No data available o) Partition coefficient: n-octanol/water log Pow: 0.73 - Bioaccumulation is not expected., (Lit.) p) Autoignition temperature No data available
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Ethyl acetate in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Consult the SDS and applicable hazard classification). Climate range guidance: 2-30 C. Compatibility notes: not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE) US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Ethyl acetate is flagged as a flammable hazard in this database (Yes). Flash point: -4 C. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Ethyl acetate is listed as: Consult the SDS and applicable hazard classification. Flammable liquids (Category 2), H225 Eye irritation (Category 2A), H319 Specific target organ toxicity - single exposure (Category 3), Central nervous system, H336
Dry Chemical fire suppression is generally recommended for Ethyl acetate (C4H8O2). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Ethyl acetate. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.